Pulp & Paper

Case:

FOULING PREVENTION IN RED LIQUOR EVAPORATORS

PULP MILL | SOUTH AFRICA

 
By preventing fouling in red liquor evaporators, energy efficiency was improved by over 50% and operational time increased by 25%.

ISSUE

 

The customer has three effect evaporators in series. The evaporators use steam to evaporate water from red liquor to increase dry solid content to over 50%. The steam circulates from the first effect to second and fourth, and finally in the condenser. The evaporators get fouled by calcium-based fouling, and this causes issues in the evaporators’ tubes.

SOLUTION

 

The fouling prevention solution uses a high-power ultrasonic field directed at the red liquor flowing through the evaporator pipes. This ultrasonic field induces sonocrystallization, altering the crystal structure of calcium-based fouling and preventing it from attaching to the evaporator’s tubular structure.

RESULTS 

 

Ultrasonic treatment of red liquor has been shown to increase the period between washes by more than 60% and the energy efficiency improvement in evaporators by more than 50%.

Additionally, the evaporation rate increased by more than 6%, and the operational time by 25%.

50+ % INCREASE IN ENERGY EFFICIENCY

6+ % INCREASE IN EVAPORATION RATE

LESS MAINTENANCE NEEDS

Contact our experts for more information